물 자연 그리고 사람 - 물로 더 행복한 세상을 만들어가겠습니다.
HOME성과논문실적

논문실적

Development of Rapid Water Monitoring Method using Direct Mass Spectrometry 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
Development of Rapid Water Monitoring Method using Direct Mass Spectrometry
학술지명 IWA (the international water association) 저자 이선홍,이은지,김윤석,최재원
발표일 2019-10-21

Aquatic ecosystems are threatened on a global scale by a variety of chemical contaminants as well as destructive land-use or water-management practices. Direct chemical contaminant measuring techniques will play an important role to monitor water quality. In the present study, Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) equipped with newly optimized headspace technique was tested to evaluate monitoring availability of 40 organic compounds in aqueous samples. In the fugacity approach (closed system, steady-state assumption) transport of chemicals into the headspace is highly correlated with Henry’s constant. Fast analytical techniques utilizing direct mass spectrometry have greatly simplified the process of contaminant monitoring in aqueous samples, particularly volatile organic compounds.

목록