물 자연 그리고 사람 - 물로 더 행복한 세상을 만들어가겠습니다.
HOME성과논문실적

논문실적

배급수관망에서의 누수복원량 산정방법 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
배급수관망에서의 누수복원량 산정방법
학술지명 대한상하수도학회지 저자 김경필,진샘물,구자용
발표일 2019-08-01

Waterworks facilities inevitably experience some amount of leakage even if there is a lot of investment or state-of-the-art
technology that is applied such as DMA(District Metered Area) system construction, leakage detection, repair, pipe
rehabilitation, etc. The primary reason is the leakage is naturally restored over time. In the UK, this restoration characteristic
is defined as NRR(Natural rate of rise of leakage) and used to decision making for prioritizing active leakage control
of DMAs. However, this restoration characteristic is well recognized, but researches on NRR in the water distribution system are insufficient in Korea. In this study, the estimation method of NRR was developed suitable for applicating in Korea considering of SCADA data, water infrastructure, and water usage patterns by modification of the UK's NRR method. The proposed method was applied to 9 DMAs and verified it's applicability by comparing with the other water loss performance indicators. It is expected that the proposed method can be used to support decision making for sustainable NRW(Nor-revenue water) management in the water distribution system.