물 자연 그리고 사람 - 물로 더 행복한 세상을 만들어가겠습니다.
HOME성과논문실적

논문실적

Experimental study of the impact of Reynolds number and chlorine concentration on manganese concentration in pilot-scaled water distribution system 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
Experimental study of the impact of Reynolds number and chlorine concentration on manganese concentration in pilot-scaled water distribution system
학술지명 2019 Eco-Smart Water Conference for Next Generatio 저자 김경필,최두용,김상현,김현준,이정섭,고동원
발표일 2019-08-26

Discolored water is a major complaint about water distribution system s and has been reported widely around the world (Boxall and Prince, 2006). The d iscoloration is frequently due to suspended particulates triggered by rehabilitation or replacement of the pi pes in the system.
The suspended particulates can be generated by exposure of the pipeline system to source water with organic and inorganic material s , fitting corrosion and lining erosion, biological growth, and chemicals and materials from treatment proc esses. Manganese oxide is one of the dominant material s caus ing discolored water. Manganese frequently flows into the pipeline system in the dry season and can be easily converted into manganese oxide by react ion with a disinfectant such as chlorine. Furth ermore, manganese oxide is physically and chemically accumulated on the pipe , and the chemical and hydraulic conditions of the pipeline system can affect the accumulation rate of the manganese. In this study, we explored the impact s of the Reynolds number and chlorine concentration on the manganese concentration in pipeline system s . An experimental pilot scale water distribution system was designed and fabricated and manganese concentration was measured under various conditions.

목록