물 자연 그리고 사람 - 물로 더 행복한 세상을 만들어가겠습니다.
HOME성과논문실적

논문실적

Calibration and Measurement Capability Improvement of Gravimetric Flowmeter Calibration System for Liquid 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
Calibration and Measurement Capability Improvement of Gravimetric Flowmeter Calibration System for Liquid
학술지명 ISFMFE2016 저자 심동혁,부창훈,이동근
발표일 2016-10-20

We have a large flow calibration facility, in which it can measure maximum flow rate 2,700 m3/h, and maximum pipe diameter 800 mm similar to developed country. In this study, we find the dominant factors related to the uncertainty of weight and time measurement for gravimetric flowmeter calibration system. As a results of improving the system, the uncertainty of weight, time and combined has been improved 1.396×10-4, 1.850×10-4 and 2.332×10-4. So calibration and measurement capability got 0.08 percent of the relative expanded uncertainty for maximum flow rate using the coverage factor(k=2).

목록