물 자연 그리고 사람 - 물로 더 행복한 세상을 만들어가겠습니다.
HOME성과논문실적

논문실적

Corrected normalized permeate flux for astatistics-based fouling detection method inseawater reverse osmosis process 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
Corrected normalized permeate flux for astatistics-based fouling detection method inseawater reverse osmosis process
학술지명 Desalination and Water Treatment 저자 임재림,박범석,이영주,김수한,김민석,이상호
발표일 2016-04-01

In the real-field application, the operation conditions for seawater reverse osmosis (SWRO) processes such as pressure, temperature, recovery rate, and feed concentration vary, which changes the permeate flow rate with no fouling. In order to detect fouling from the fluctuating permeate flow rates due to various operation conditions, they should be normalized. However, the normalization method using ASTM D4516 method still produces the fluctuation in the normalized permeate flow due to poor selections of osmotic pressure and temperature correction factor (TCF) equations, which do not reflect the characteristics of feed water and reverse osmosis membrane in the field very well. This work introduces the corrected normalized permeate flux (NPF) using the fitted osmotic pressure and TCF equations to minimize the fluctuation during a non-fouling situation and suggests a statistical approach to detect fouling by comparing the mean values of two groups with different variances. The laboratory-scale SWRO experiments with randomly changing operation
conditions verify that the corrected NPF and the statistics-based fouling detection method works very well to find the early stage of fouling by humic acid. In addition, the fitted TCF equation affects the performance of the fouling detection method more than the fitted osmotic pressure equation.