물 자연 그리고 사람 - 물로 더 행복한 세상을 만들어가겠습니다.
HOME성과논문실적

논문실적

Optimization of ‘Clean-in-Place’Procedure in Daesan Industrial Water Treatment Plant to save Energy 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
Optimization of ‘Clean-in-Place’Procedure in Daesan Industrial Water Treatment Plant to save Energy
학술지명 2015 8th International Desalination Wrokshop 저자 이영주,임재림,이경혁,정용문,박준수
발표일 2015-11-20

A central supplying industrial water treatment plant is receiving attention (Quevedo, N., Sanz, J., Lobo, A., Temprano,J. and Tejero, I. 2012). Because industries want to receive pure water safety and save the cost for self-production of pure water. K-water Daesan industrial water treatment plant was the first brackish water reverse osmosis plant supplying industrial water to Hyundai Oilbank, Samsung Total, Lotte Chemical, LG Chemical, and KCC in Seosansi. This plant consist of microfiltration (MF) as a pre-treatment and reverse osmosis (RO) membrane and produce 119,000 m3/day of industrial water. However, plant was faced with a problem which is increasing operation cost due to lack of experience to manage RO plant. One of big problem is clean-in-place (CIP). The period and cost of CIP are increased than in the past and durability of RO membrane is decreased. Therefore, adequacy of current CIP method have to be evaluated. In this study, we performed phased evaluation of CIP using RO pilot to get efficiency of CIP and comprised data between real RO plant and pilot to confirm applicability. Finally, optimum method of CIP fined by pilot test was applied to real RO plant.

목록