학술지명 Urban Water Journal 저자 김도환,김주환,최두용,이두진
발표일 2015-03-01

Pressure measurements provide valuable insights for managing water supply systems by tracking time-dependent hydraulic transients. In this study, we report on two pressure-monitoring issues ? sampling location and sampling interval ? by analyzing a valve-induced transient event that was not recorded in the 1-min timestamp pressure generated by the existing supervisory control and data acquisition (SCADA) system of a real water transmission line in the southern part of Korea. Field measurement data show that the measured pressure magnitude is influenced by the sampling location, which depends on pipe connectivity and distance from automatic control valve, and by the sampling interval, which is sensitive to network
size for wave propagation. Based on the findings of the field experiments, a pressure-measurement method is proposed by employing numerical transient simulation and spectral analysis of pressure waves.