물 자연 그리고 사람 - 물로 더 행복한 세상을 만들어가겠습니다.
HOME성과논문실적

논문실적

고도처리공정에서 다양한 수질에 따른 미량유기오염물질 제거특성 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
고도처리공정에서 다양한 수질에 따른 미량유기오염물질 제거특성
학술지명 한국수처리학회 저자 권순범,유영범,최양훈,김충환
발표일 2015-10-30

Mobile Water Treatment Plant (MWTP) was evaluated for operational parameters, design
values and especially removal efficiency of taste and odor compounds (T&Os) as organic
micropollutants (OMPs). Geosmin and 2-MIB with a high concentration level i.e., spiked with a range
200 ng/L to 1,300 ng/L of initial concentration could be totally removed by MWTP when AOP,
O3/GAC, AOP/GAC hybrid process was operated. It found that removal of T&Os by O3 oxidation
and GAC adsorption was affected by a several factors i.e., reaction parameters such as initial
concentration and type of organic compounds, water property, especially particulate matters, O3 dosage,
retention time.

목록