Membrane filtration process in water treatment can be an efficient and economical way to separate contaminants, which suspended in water. Membrane fouling is a main problem in maintenance control during filtration processes. It is important to predict and reduce membrane fouling that included inorganic/organic fouling, colloidal fouling, and biofouling. SDI (Silt Density Index) is a measure for the fouling potential, however, it is limited to predict surficial property of fouling substance and to get similar results in real field comparing theoretical approach. MCI (Membrane Cleaning Index) is complemented of these limitation. In this study, the membrane fouling index was evaluated and confirmed that MCI can be applied as a useful tool to predict the fouling capacity and to propose a suitable cleaning solution and method.
Membrane mini-modules, used in this study, consist of hollow fiber membrane cell including cross-flow type. The MCI tests were performed with manufactured MCI evaluation apparatus. MCI were determined by backwashing and circulation process during cleaning in place (CIP) in static pressure condition (0.5 bar). As cleaning solution, sulfuric acid, citric acid, sodium hydroxide, and sodium hypochlorite were used.
Comparing the MCI by cleaning solution, it is possible to predict the cleaning rate and to select effective chemicals for decreasing membrane fouling. 
In additionally, MCI can be used as criteria to decide cleaning order, which is multiple cleaning processes combined with acid and base chemical solution during membrane cleaning. A study of the constructing database of membrane cleaning index will be progressing as planned.