Reduction of phosphorous at WWTP combined with DAF and A2/O 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
Reduction of phosphorous at WWTP combined with DAF and A2/O
학술지명 Desalination and Water Treatment 저자 YTGuan,권순범,독고석,김두일
발표일 2014-04-28

Regulation of the phosphorous (P) concentration in effluent from the Jinju wastewater treatment
plant (WWTP) in southern part of Korea has recently been strengthened, with a reduction
in the acceptable P limit from 2.0 to 0.2 mg/L. Various treatment processes have been
introduced and applied to meet the regulation, after use of biological treatments such as conventional
activated sludge, anoxic?oxic (A/O), and anaerobic?anoxic?oxic (A2/O) treatments.
The present work introduces a hybrid system of A2/O and dissolved air flotation (DAF)
treatment to remove P from the effluent. The total capacity of the WWTP is 190,000m3/d. The
dimensions of the DAF basins are 8m (width), 16m (length), 4.2m (height), 6 basins, and the
capacity is 2,995m3/d. The retention time and recycling ratio are 19 min and 15%,
respectively. The surface loading rate is 240 m/d. Operation of the system with A2/O+DAF
has already commenced and total P was reduced from 2.18 to 0.03 mg/L. A2/O+DAF
treatment improved the mean effluent concentrations of total phosphorus, chemical oxygen
demand, and suspended solids by approximately 70, 29, and 27%, respectively, compared
with the corresponding levels in effluent after A2/O treatment alone.