수직형 정수처리시설의 압력조건에 따른 운영관리 평가 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
수직형 정수처리시설의 압력조건에 따른 운영관리 평가
학술지명 한국수처리학회 저자 서인석,김성수,김남경,채선하
발표일 2014-08-29

A pilot test was caried out to evaluate the operation and management of a vertical type water treatment plant (WTP), which consists of ultrafiltration (UF), ozonation, granular activated carbon (GAC), and UV oxidation. Five different cases were tested according to pressure conditions. Operation pressures were controled by adjusting the outlet valve of UV oxidation process and pressure data of unit processes were monitored during the pilot test. As a result, the differential pressures of GAC process for the tests 1 to 5 were 0.19, 0.28, 0.46, 0.71, and 0.15 kgf/㎠, respectively and trans-membrane pressures of UF process were 0.50, 0.60, 0.65, 0.75, and 0.85 kgf/㎠, respectively. These results imply that the operation pressure of a unit process affects that of another unit process, which impacts the performance of all the unit processes. In addition, the higher total differential pressure(GAC differential pressure+TMP), the more use UF active power. Therefore, the pressure control should be very important to operate the vertical type WTP.