Fouling Autopsy of Hollow-fiber MF membranes in Desalination Water Treatment Plant |
---|
학술지명 IWA
저자 이경혁,임재림,이영주,권명기
발표일 2014-10-23
|
Fouling in membrane filtration processes is problematic but inevitable as it occurs with the retention of contaminants that accumulate on the membrane surface. The causes of fouling are often specific, depending upon feed water constituents, the membrane, and the operation. Therefore, it is desirable that investigation is performed on fouled membrane of the affected plant. This technique is known as membrane autopsy, which identifies the cause of poor membrane performance, and gives the opportunity to mitigate the problem and improve future plant design. |