물 자연 그리고 사람 - 물로 더 행복한 세상을 만들어가겠습니다.
HOME성과논문실적

논문실적

BULB-TYPE MODEL TURBINE PERFORMANCE TEST BASED ON IEC 60193 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
BULB-TYPE MODEL TURBINE PERFORMANCE TEST BASED ON IEC 60193
학술지명 AFORE2013 저자 Zhang,오용환,조용
발표일 2013-11-06

For the rehabilitation of Namgang hydropower plant, new bulb turbine has been developed by CFD simulations. In order to confirm the performance of the newly developed turbine, the small-scale model turbine shown in Fig. 1 has been manufactured. The diameter of the model runner blade is reduced to 350 mm from 3.0 m of the prototype one. The rotational power from a runner is transferred to an electric magnetic dynamometer through bevel gear, and the rotational speed is measured by a magnetic tachometer. For the torque measurement a static hydraulic bearing system is installed in the bulb, and the torque can be measured by force transducer connected with a static hydraulic bearing. The test has been conducted at the head between 3.4 m and 7.2 m and Reynolds number is 5.88×106 which shall meet the requirement of IEC 60193[1]. Various tests for efficiency, runaway speed, cavitation, and so on, has been carried out, and the model hill chart and correlation between runner blades and guide vanes has been obtained.

목록