Effect of flux fluctuation on the fouling in membrane water treatment system for smart water grid
학술지명 Desalination and water treatment 저자 박종율,임재림,김종오,김수한
발표일 2013-03-18

Smart water grid is a water network with communication to save water and energy. In smart
water grid, decentralized water management system is more suitable than the conventional
centralized system. Membrane process can be a potent option of water treatment system for
decentralized water management system due to stable product water quality regardless of
periodic changes in water production rate (flux fluctuation) to meet a real-time water demand. In this study, the effect of flux fluctuation on membrane fouling was investigated using a simple microfiltration (MF) fouling model for field application. The fouling model was verified by operation data of a pilot-scale MF plant with two commercial MF membrane modules (72m2 of membrane area). From the MF simulation results, we found that periodic change in flux can induce higher fouling than the constant flux and the fouling becomes
more severe as the range of the fluctuation increases. It was also found that the frequency of flux fluctuation was not related to fouling, if the average flux and the fluctuation range were not changed. Therefore, the range of flux fluctuation should be carefully designed when flux fluctuation in inevitable in membrane water treatment for smart water grid.