전기가열로 인한 심층 지반의 온도 및 강도 변화 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
전기가열로 인한 심층 지반의 온도 및 강도 변화
학술지명 한국지반공학회 저자 한희수,박민철,박서규,임은상
발표일 2013-03-21

To analyse the thermal behavior of deep weak soil in this study, 4-meter length electric heating pipe was installed in field. It was made by Ni-Cr wire and consumed 1kw/m, which was designed to show 450℃ surface temperature. Also, it was installed at 3~7 m area below soil surface, three thermometer were installed at 5m depth to monitor the temperature variations. The results of in-site test were similar to line source model and program, the resulted graph showed log pattern curves. Therefore, the soil heating through pipe in ground could be used to soil improvement successfully. In addition, the vapor caused by soil
heating was emitted to upward and the most heat was transferred to horizontal direction.