물 자연 그리고 사람 - 물로 더 행복한 세상을 만들어가겠습니다.
HOME성과논문실적

논문실적

계측시스템을 이용한 현장 제방의 안전율 평가 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
계측시스템을 이용한 현장 제방의 안전율 평가
학술지명 한국지반환경공학회 저자 박민철,김석주,한희수,임은상
발표일 2013-12-24

In this research, stainless steel and heat-shrinkage tube were used for new TDR sensing line to solve the problems of ordinary TDR system. The new TDR line improved the sensitivity of water content and endurance, and reduced the data noise. The saturation degree test and acryl model test were done by revised TDR sensor. From the results, without additional data filtering and quantitative analysis, the raw data was separated into 3 zones; saturated, unsaturated and dried zones easily. In addition, the revised TDR sensor was installed in large-scale embankment model to do the seepage test. The raw data of the model tests showed the distributed seepage behaviors and separated zones clearly, which were almost the same tendencies of the lab test
results.