심층지반의 전기가열에 따른 거동해석 |
---|
학술지명 한국지반공학회
저자 이금성,박민철,임은상,한희수
발표일 2013-10-17
|
In this study, we developed the electric heat pipe and applied for deep soil improvement. The developed heat pipe for deep soil is 4 m-length and consumes 1 kW/m. It was installed in 3.5 ~ 4.5 m below ground surface and heated for 96 hours(48 hours, 2 times). The temperature variation and vapor pressure caused by electric heating was measured by the thermometer and pressure gauge which were installed in the ground(5.0 m), and the tip resistances were measured by static electronic piezo-cone penetration test(CPT). As the results of experiments, 2-order polynomial curve was shown to adjust the variation of tip resistance and the temperature distribution with the horizontal distance from electric heater, whose R2 value is close to 1. In |