물 자연 그리고 사람 - 물로 더 행복한 세상을 만들어가겠습니다.
HOME성과논문실적

논문실적

Effect of organic loading and influent source on energy production at the multi baffled single chamber microbial fuel cell 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
Effect of organic loading and influent source on energy production at the multi baffled single chamber microbial fuel cell
학술지명 CEMEPE 저자 유재철,김홍석,김지연,김병군
발표일 2013-06-27

The power densities were different according to the influent sources and were increased with COD loading rates regardless of the influent source. CW produced the maximum power densities (PDmax) of 2.74 W/m3 (HRT 12h) and 3.51 W/m3 (HRT 6h). IP showed 6.97 W/m3 (HRT 6h) and 8.96 W/m3 (HRT 2h). Using EP, the PDmax were 2.22 (HRT 6h), 3.49 (HRT 4h), 6.01(HRT 2h), and 9.56 W/m3 (HRT 1h). In case of DW, the MFC produced 6.56 (HRT 6h), 9.86 (HRT 4h), 14.6 (HRT 2h), and 19.5 W/m3 (HRT 1h). However, MFC didn’t show expected power density although the high organic wastewater such as CW or DW were used. This study indicated that wastewater characteristics such as sorts and composition of easily biodegradable organic compounds would affect power generation of MFC. 

목록