오비트랩 방식의 고분해능 정밀질량 분석방법을 적용한 수질 트리아진계 농약류의 미량분석방법 |
---|
학술지명 한국환경분석학회지
저자 최재원
발표일 2012-10-11
|
Full scanning technology by high resolution and accurate mass spectrometer (HRAM) is one of most advanced methodology for identification and quantification of organic compounds. In this study, column switching technique based online preconcentration method was combined with high resolution full scan mass spectrometer to measure trizazine pesticides in water. After parameter optimization of online preconcentration, 1 mL volume of filtered sample was used. For instrumental analysis, electrospray ionization (ESI) and orbitrap mass spectrometer with 100 - 600 amu scan range at 50,000 resolving power was tested. By this approach, available mass accuracy below 2.7 ppm (parts per million of monoisotopic mass), calibration linearities above 0.997, method detection limit (MDL) for 0.2 - 1.8 pg/mL, recoveries for 102 - 117% and repeatabilities below 4.3 % were obtained. Method performance of online preconcentration with HRAM method is comparable to the state-of-the-art solid-phase extraction (SPE) with triple quadrupole mass spectrometer (MS/MS). |