ERROR CHARACTERISTICS OF MULTI-PATH ULTRASONIC FLOWMETER |
---|
학술지명 ISFMFE
저자 조용,이동근
발표일 2012-10-26
|
Multi?path ultrasonic flowmeter has been used as an accurate flow measurement method and is on a growing trend. However, the installation standard has been not established yet, so it led to lots of confusion on the field installation. Therefore, it is in need of minimum straight run to ensure the accuracy of the measurement from the flow disturbance factors. So that experiments were performed by using multi-path flowmeters that have less than ?0.5% accuracy, 4-path 1 unit, 2-path 1 unit are of foreign-make, 5-path 2 units are of domestic products, to determine straight run under the above conditions. We carried out experiments repeatedly considering straight run, velocity and suggested installation standards on multi-path ultrasonic flowmeter satisfying the tolerance |