밸브하류에 설치된 건식초음파유량계의 편차특성
학술지명 유체기계공업학회 저자 이동근,조용
발표일 2012-08-01

This study was performed to found out the deviations for clamp-on type ultrasonic flowmeter installed in downstream of valves. It was selected three types of two-path flowmeter mainly used for K-water as test. Experiment carried out to confirmed characteristics of deviation depending on the sensor location, straight run and maker for 1-path, 2-path and 4-path combined 2-path flowmeter. It was selected two kinds of valves with 100% and 50% opening, butterfly valves and gate valves, for flow disturbance factor. Finally, we suggested number of sensors by maker, straight run and installed location of sensors satisfying the tolerance depending on the experiment results.