Even though there is a public health threat if biofilm of distribution system causes issue on drinking water, the study on biofilm is not examined well. The objective of this study is to examine the characteristics of biofilm formation according to the lining material of pipeline in the distribution system using annular reactor in lab-scale and to survey the microbial character of biofilm using field samples. Eight different types of coupons according to lining material of pipeline were installed in annular reactor and operated in continuously with the same condition of the distribution system. With the continuous operation, diverse coupons were collected on timely basis and investigate the character of microbial community using pyrosequencing. Also, four field samples were collected to investigate the microbial community and eleven microbial items were surveyed including E. coli, coliforms, Aeromonas, etc. Two sample sites, DW and GM, showed higher concentration of microbes than the others. Especially Aeromonas which shows disinfection resistance was detected in these two samples. For DW sample, sequencing was conducted for the typical colonies after detecting heterotrophic bacteria. The majority of the colonies were classified as Bacillus and the other colonies were classified as Lysinibacillus, Sphingomonas, Streptomyces Microbacterium, Rathayibacter, Hymenobacter, Paenibacillus.