물 자연 그리고 사람 - 물로 더 행복한 세상을 만들어가겠습니다.
HOME성과논문실적

논문실적

친수지역 강변여과수 열원을 활용한 냉난방시스템 개발 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
친수지역 강변여과수 열원을 활용한 냉난방시스템 개발
학술지명 한국신재생에너지학회 2011 춘계학술대회 저자 김대근,문종필,조용
발표일 2011-05-26

A water-source heat pump system has been developed for cooling and heating of a green house on the waterfront in Jinju. In order to supply a heat source/sink of water in alluvium aquifer to the heat pump system, the riverbank filtration facility (two pumping wells and one recharge well) for water intake and injection has been constructed. To pump and recharge water sufficiently, the geometric design such as depth and diameter for the wells have been completed, and details of the well such as slot size and length of the screen and filter pack size have been designed based on the practical and theoretical design method including D30 technique. For the investigation of the hydrogeological characteristics, step-drawdown test, long-term pumping test, and recovery test have been carried out for two developed pumping wells. Step-drawdown test has been performed on 4 step flowrates of 150, 300, 450, 600 m3/day for 1 hour, and long-term pumping test on flowrate of 500 m3/day for 24 hours, and recovery test for 6 hours. Since the underground water filtrated by riverbank is flowing smoothly into the well, the water level goes down slightly for the long-term test. Consequently, the stable pumping flowrate for two pumping well has been predicted at least over 1,647 m3/day which is larger than the flowrate of 1,000 m3/day for a 60 RT heat pump system.