물 자연 그리고 사람 - 물로 더 행복한 세상을 만들어가겠습니다.
HOME성과논문실적

논문실적

버터플라이밸브가 설치된 관로 내의 단회선 초음파 유량계의 성능 예측 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
버터플라이밸브가 설치된 관로 내의 단회선 초음파 유량계의 성능 예측
학술지명 유체기계공업학회 저자 박주영,이동근,김상균,김영준,고재명
발표일 2009-12-04

The performance of a single path ultrasonic flowmeter is influenced by disturbance of the valve and the pipe fitting in the pipe line. In this paper describes flow performance prospects for a single path ultrasonic flowmeter. The single path ultrasonic flowmeter was installed before and after butterfly valve. Computational fluid dynamics (CFD) are used numerically to predict performance of ultrasonic flowmeter due to installed a butterfly valve in the pipe line. The simulations are carried out for several operating conditions, open rate of disk, velocity of fluid, and the distance between the flowmeter and valve. The results show that the disturbance of butterfly valve are one of the main reason for flow rate error.

목록