유속과 유동교란인자에 의한 전자식 및 초음파유량계의 오차특성 연구
학술지명 유체기계공업학회 저자 박종호,이동근
발표일 2009-11-09

In this study, the effect of flow disturbance such as contraction, expansion pipe and velocity deviation from low velocity of 0.1㎧ to 2.5㎧ on the error characteristics of the flowmeter was studied. Flow experiments using flowmeter calibration facility of K-water were undertaken for the cases of ultrasonic flowmeter based on transit-time method and electromagnetic flowmeter. Experimental results are presented that measurement error of expansion pipe are larger than contraction pipe. It is shown that the minimum straight length were required to remain of ±0.5% error for electromagnetic flowmeter and ±2.0% error for ultrasonic flowmeter.