Sewer Rehabilitation Project (SRP) is planed, designed and constructed to perform its intended performance as sewerage
delivery systems. Recently, a subject of performance evaluation methodology development for SRP has become a great deal
of concern among researchers in Korea. From the view point of Sewage Treatment Plant (STP), however, the estimation of
improvement efficiency for SRP is in lack of reliability due to the fact that affections for the treatment efficiency and operating
condition are not reflected on SRP design and construction. In this study, statistical methodology was used in the analysis of
data, which are taken during 1,186 days (1st Jan. 2005 - 31th Mar. 2008) from the influent, effluent and operating conditions of
full-scale STP(25,000m3/d). Then the effect of SRP on the influent characteristics and operating conditions changing was
compared and evaluated. Results from the statistical evaluation show that SRP causes characteristic changes in influent and
exerts a significant effect especially on the performance of STP.