Uncertainties in measurements of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in ambient waters were estimated using large volume water sampler with polyurethane foam. According to the guidance of uncertainity measurement by International Standardization Organization, optimal procedure model was set up and then calculation and combination of each uncertainty source were performed. Factors affecting PCDD/F concentrations in ambient waters were selected as uncertainties of sampling, spike of internal standards, extraction of polyurethanefoam (PUF), and instrumental analysis. The major factor for each uncertainty procedure was instrumental analysis, and in the order of extraction of PUF, spike of internal standards and sampling. Relative amount of the uncertainty in the present study was estimated to be 13% to the measured concentrations of PCDD/Fs, consistent with the values for serum analysis in an earlier study.