Effect of Pollutant Load Reduction to Reservoir Water Quality 게시글의 제목, 학술지명, 저자, 발행일, 작성내용을 보여줌
Effect of Pollutant Load Reduction to Reservoir Water Quality
학술지명 ISRLE 저자 박상영,정선아,이요상,이혜숙
발표일 2007-10-17

Integrated management of watershed, river and reservoir has become an important issue in water quality management field. Modelling technique is widely used and considered as a scientific and systematic tool for water quality management of river and reservoir. The integrated approach of watershed and reservoir modelling could be efficient to water quality management authority because pollutants from upper watershed are closely connected to the water quality in reservoir. 
In this study, water quality variation by pollutants control facilities was evaluated using linkage of watershed and reservoir model in the Yongdam watershed reservoir, Korea. In the study watershed, pollutant control facilities are mainly waste water treatment plant (WWTP) and some of them are a small-scale WWTP. These facilities are used to remove pollutants from watershed and discharge to stream and river. So, it is important to analyze pollutants removal effects of these facilities and predict water quality variations of stream and rewervoir.
Hydrological Simulation Program FORTRAN (HSPF), developed in U.S. EPA, has been widely used in watershed management and TMDLs (Total Maximum Daily Loads). HSPF was used to simulate watershed pollutant load and the pollutant removal effect of WWTP for the study watershed. CE-QUAL-W2, developed in U.S Army Corps of Engineers, is two-dimensional laterally averaged hydrodynamic and water quality model for river and reservoir.
The average pollutant removal effects of WWTP are 76.5% of BOD, 24.6% of TN and 27.2% of TP in small-scale WWTP, and 98.6% of BOD, 70.9% of TN and 66.6% of TP in normal-scale WWTP. HSPF and CE-QUAL-W2 were calibrated against the field measurements data of BOD, TN, TP for the 5 tributaries and 10 in-reservoir monitoring sites. The calibration results showed a reasonable agreement with the field measurements at all parameters. Water qualities such as BOD, TN, TP and chlorophyll-a, were simulated for the upper layer of Youngdam reservoir according to the WWTP operation scenarios. 
The average effect of WWTP operation were 0.01mg/L (maximum 0.03 mg/L) of BOD and 0.001mg/L (maximum 0.004 mg/L) of TN in front of the dam. The water qualities simulation results were various in each site and layer. There were, however, no significant effect in TP and  chlorophyll-a concentration by the WWTP operation. This result could be thought that these water quality parameters are more influenced by non-point sources in rainy periods than dry period.