| 저유속영역에서 대구경 전자기 유량계의 오차특성 연구 |
|---|
|
학술지명 대한기계힉회
저자 이동근
발표일 2008-05-21
|
|
The large size electromagnetic flowmeter was tested to investigate the variation of its error characteristics in the range of low velocity under 0.6 m/s using flowmeter calibration system. For the two case of valve opening rate 100 % and 50 %, these tests were undertaken three times each for twelve velocity condition from 0.05 ㎧ to 0.6 ㎧ with increment of 0.05 ㎧.It is shown that error characteristic of electromagnetic flowmeter was stabilized within ±0.4 % of rate both higher than 0.25 ㎧ of velocity condition and 50 % of valve opening position. But, measurement deviation of flowmeter for φ400 ㎜ and φ600 ㎜ was out of expected deviation range. It is necessary to correction with calibration. In conclusion, error characteristic of electromagnetic flowmeter wasn't changed proportion to its size. |